Document LTM0884 rev 2e

 

Water Chemistry

Check water chemistry regularly and maintain within recommended levels. Standards vary in different residential and commercial applications. Follow all local applicable codes.

NOTICE

Failure to heed the following may result in damage to equipment.

 

  • Do not allow water to flow through chiller when refinishing or acid washing a pool. Either use an installed bypass to route water away from chiller or deactivate filter pump.
  • To avoid damage to equipment, monitor and maintain chemistry within recommended levels.

CHEMISTRY LEVEL CHART

(RESIDENTIAL)

CHEMICAL POOLS SPAS
Chlorine 1.0 – 3.0 ppm 3.0 – 5.0 ppm
Bromine 2.0 – 6.0 ppm 2.0 – 6.0 ppm
Cyanuric Acid 30 – 50 ppm 30 – 50 ppm
pH 7.4 – 7.6 7.4 – 7.6
Total Alkalinity 80 – 120 ppm 80 – 120 ppm
Calcium Hardness 200 – 400 ppm 150 – 250 ppm
Total Dissolved Solids* 0 – 1,500 ppm 1,500 ppm above start-up of total dissolved solids in spas